Monitoring of Embryonic and Fetal Development Using Real Time ‘B’ Mode Ultrasound in Buffalo (Bubalus bubalis)
dc.contributor.author | Sarath, T. | |
dc.contributor.author | Singh, S.K. | |
dc.contributor.author | Arunmozhi, N. | |
dc.contributor.author | Saxena, A. | |
dc.contributor.author | Shankar, Uma | |
dc.contributor.author | Agarwal, S.K. | |
dc.contributor.author | TANUVAS | |
dc.date.accessioned | 2022-01-10T07:34:39Z | |
dc.date.available | 2022-01-10T07:34:39Z | |
dc.date.issued | 2021-05 | |
dc.description | TNV_IJVASR_50(3)_May-June.2021_44-50 | en_US |
dc.description.abstract | The present study was conducted in buffaloes which were maintained at experimental animal sheds of Animal Reproduction Division, IVRI, Izatnagar. All the experimental buffaloes (n=6) were observed for onset of estrus using a teaser bull and visual signs of estrus followed by rectal examination twice daily. Animals detected in estrus were inseminated using frozen semen of Murrah buffalo. The inseminated buffaloes were allowed for real time B-mode ultrasonographic examination at 10 days interval starting from day 20 to 120 of pregnancy. Monitoring of embryonic development was carried out by viewing embryonic vesicle diameter (EVD), Crown Rump length (CRL), embryonic heartbeat, skull and placentome through ultrasonography. The mean diameter of EV was 0.52±0.12, 1.56±0.16, 2.94±0.07, 3.80±0.14 and 6.37±0.15 cm on day 20, 30, 40, 50 and 60 of pregnancy, respectively. EVD increased with advancement of pregnancy and reached around 6.37±0.15 cm on day 60 of pregnancy. | en_US |
dc.identifier.uri | https://krishikosh.egranth.ac.in/handle/1/5810180558 | |
dc.keywords | Veterinary Science, Clinics, Buffalo, Embryo, Fetal development, Pregnancy diagnosis, Ultrasonography | en_US |
dc.language.iso | English | en_US |
dc.pages | 44-50 | en_US |
dc.publisher | TANUVAS, Chennai | en_US |
dc.relation.ispartofseries | ;3 | |
dc.subject | Veterinary Science | en_US |
dc.subject | Clinics | en_US |
dc.title | Monitoring of Embryonic and Fetal Development Using Real Time ‘B’ Mode Ultrasound in Buffalo (Bubalus bubalis) | en_US |
dc.title.alternative | Ind. J. Vet. & Anim. Sci. Res. | en_US |
dc.type | Article | en_US |
dc.volume | 50 | en_US |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- TNV_IJVASR_50(3)_May-June.2021_44-50.pdf
- Size:
- 717.17 KB
- Format:
- Adobe Portable Document Format
- Description:
- TNV_IJVASR_50(3)_May-June.2021_44-50
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: