Development and Validation of Real-Time PCR for Rapid Detection of Mecistocirrus digitatus

dc.contributor.authorSubhadra, Subhra
dc.contributor.authorKarthik, Mohanraj
dc.contributor.authorRaman, Muthusamy
dc.contributor.authorTANUVAS
dc.date.accessioned2020-02-10T06:54:24Z
dc.date.available2020-02-10T06:54:24Z
dc.date.issued2013-04
dc.descriptionTNV_PLOS_2013_8(4)1-6en_US
dc.description.abstractHematophagous activity of Mecistocirrus digitatus, which causes substantial blood and weight loss in large ruminants, is an emerging challenge due to the economic loss it brings to the livestock industry. Infected animals are treated with anthelmintic drugs, based on the identification of helminth species and the severity of infection; however, traditional methods such as microscopic identification and the counting of eggs for diagnosis and determination of level of infection are laborious, cumbersome and unreliable. To facilitate the detection of this parasite, a SYBR green-based real-time PCR was standardized and validated for the detection of M. digitatus infection in cattle and buffaloes. Oligonucleotides were designed to amplify partial Internal Transcribed Spacer (ITS)-1 sequence of M. digitatus. The specificity of the primers was confirmed by non-amplification of DNA extracted from other commonly occurring gastrointestinal nematodes in ruminants. Plasmids were ligated with partial ITS-1 sequence of M. digitatus, serially diluted (hundred fold) and used as standards in the real-time PCR assay. The quantification cycle (Cq) values were plotted against the standard DNA concentration to produce a standard curve. The assay was sensitive enough to detect one plasmid containing the M. digitatus DNA. Clinical application of this assay was validated by testing the DNA extracted from the faeces of naturally infected cattle (n = 40) and buffaloes (n = 25). The results were compared with our standard curve to calculate the quantity of M. digitatus in each faecal sample. The Cq value of the assay depicted a strong linear relationship with faecal DNA content, with a regression coefficient of 0.984 and efficiency of 99%. This assay has noteworthy advantages over the conventional methods of diagnosis because it is more specific, sensitive and reliable.en_US
dc.identifier.urihttp://krishikosh.egranth.ac.in/handle/1/5810142775
dc.keywordsDevelopment, Validation, Real-Time PCR, Rapid Detection, Mecistocirrus digitatusen_US
dc.language.isoenen_US
dc.pages1-6en_US
dc.relation.ispartofseries;4
dc.subjectVeterinary Scienceen_US
dc.titleDevelopment and Validation of Real-Time PCR for Rapid Detection of Mecistocirrus digitatusen_US
dc.title.alternativePlosoneen_US
dc.typeArticleen_US
dc.volume8en_US
Files
Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
TNV_PLOS_2013_8(4)1-6.PDF
Size:
1.84 MB
Format:
Adobe Portable Document Format
Description:
TNV_PLOS_2013_8(4)1-6
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: