Loading...
Thumbnail Image

Anand Agricultural University, Anand

Anand Agricultural University (AAU) was established in 2004 at Anand with the support of the Government of Gujarat, Act No.(Guj 5 of 2004) dated April 29, 2004. Caved out of the erstwhile Gujarat Agricultural University (GAU), the dream institution of Sardar Vallabhbhai Patel and Dr. K. M. Munshi, the AAU was set up to provide support to the farming community in three facets namely education, research and extension activities in Agriculture, Horticulture Engineering, product Processing and Home Science. At present there seven Colleges, seventeen Research Centers and six Extension Education Institute working in nine districts of Gujarat namely Ahmedabad, Anand, Dahod, Kheda, Panchmahal, Vadodara, Mahisagar, Botad and Chhotaudepur AAU's activities have expanded to span newer commodity sectors such as soil health card, bio-diesel, medicinal plants apart from the mandatory ones like rice, maize, tobacco, vegetable crops, fruit crops, forage crops, animal breeding, nutrition and dairy products etc. the core of AAU's operating philosophy however, continues to create the partnership between the rural people and committed academic as the basic for sustainable rural development. In pursuing its various programmes AAU's overall mission is to promote sustainable growth and economic independence in rural society. AAU aims to do this through education, research and extension education. Thus, AAU works towards the empowerment of the farmers.

Browse

Search Results

Now showing 1 - 1 of 1
  • ThesisItemOpen Access
    EFFECTS OF MONOPOLAR AND BIPOLAR ELECTROSURGICAL UNIT ON ABDOMINAL WALL, MESENTERIC ARTERIES AND SMALL INTESTINE OF RABBITS (Oryctolagus cuniculus
    (Anand Agricultural University, Anand, 2011) ALASE ASHWINI LAXMAN; Dr. D. B. PATIL
    Electrosurgery is one of the most often and routinely used surgical tool for tissue cutting and coagulation, with thermal damage extending to hundreds of micrometers. The desired therapeutic result of electrosurgery is controlled tissue destruction at the site of the active electrode, with no effect at any other location, including the site of the dispersive electrode. However, the degree of thermal damage produced by this instrument is often suspected to be extensive. This study was undertaken to assess the thermal damage caused by Monopolar and Bipolar electrocoagulation at clinically relevant different power outputs and durations of applications on mesenteric arteries having 2 mm diameter, small intestine and abdominal wall in rabbits in order to avoid the side effects for the safer surgery without hazards. After the rabbits were anesthetized with xylazine-ketamine-diazepam